首页    Thread End - Series: 07
thread-end-500x500

Thread End - Series: 07

机器设备

MACHINERY

Thread End - Series: 07

Size:1" thru 4"

Operating Temperature:To 225°F with standard materials
To 300°F with optional materials

Maximum Differential:5 psi

Maximum Containment:25 psi

Design Standard

The PDC “Thread End” Series Butterfly Valve is available in sizes from 1″ thru 4″.

Specifications

Size Range:

1" thru 4"

Temperature:

To 225°F with standard materials
To 300°F with optional materials

Body Style:

Female Threaded Pipe

Design Features

  • Simplicity of construction
  • Close tolerance angle seated disc machining for minimal leakage.
  • Thread end construction provides maximum economy by eliminating need for mating flanges.
  • Thread end valves can be customized for electric and pneumatic actuation.

Applications

  • Blower Equipment
  • Compressor Equipment
  • Boiler Equipment
  • Environmental Systems
  • V.A.C
  • Industrial Process Furnaces
  • Oil Gas/Refining
  • Power Generation/Co-Generation
  • Water & Sewage
  • Stationary Engines
  • Chemical Equipment
  • Mining Equipment
  • Gas Recovery Systems

Standard Materials and Seat Construction

Body: Cast Iron
Disc: Carbon Steel
Shaft: Stainless Steel
Seals: EPT O-Rings
Seat: Angle

Optional Materials and Seat Construction

Seals: Viton O-Rings suitable for temperatures to 300°F
Seat: Swing Thru

Chart or Graph

Typical Dimensions: 1″ thru 4″

Style A
Thumb screw friction lock permits an infinite number of disc positions.

Style C
Locking handle friction lock permits an infinite number of disc positions.

Size (NPT) A B C D E F Approx. Wt. (Lb)
1 1.04 2-3/4 1-1/2 1-9/16 2-1/2 2-7/8 3.5
1-1/2 1.6 2-3/4 1-1/2 1-9/16 2-1/2 2-7/8 3
2 2.04 2-7/8 1-5/8 1-11/16 2-7/8 3-5/8 4
2-1/2 2.44 3-5/8 2-1/16 2 3-1/2 4 5
3 3.04 3-7/8 2-3/8 2-11/16 4-1/8 4-3/4 6
4 4.02 4-1/2 2-7/8 2-15/16 5-1/8 5-5/16 10

MAX ∆P is 5 PSI. MAX containment pressure is 25 PSI

Cv Values for PDC Thread End Series Valves

By definition, Cv is the flow coefficient of a control device or flow restriction. Cv is defined as the number of US gallons of 60°F water per minute which will flow through the given restriction with a one pound per square inch pressure drop.n restriction with a one pound per square inch pressure drop.

Cv Values

(Flow in GPM of 60°F water at 1 psi pressure drop Specific Gravity=1)

VALVE SIZE Disc Angle, Degrees
  10 20 30 40 50 60 70 80 90
1 1 3.5 8 12 16 20 32 42 45
1.5 2.1 4.5 9 17 31 51 80 137 219
2 3.5 7 15 27 51 83 130 222 355
2.5 4.9 10 22 39 73 119 186 317 508
3 8 16 34 61 113 185 289 493 789
4 13 28 60 106 198 323 505 862 1380

Downloads